{"product_id":"staubli-original-mc4-solar-pv-connector-open-crimp-contacts-sol-mc4-11014112","title":"Stäubli Original MC4 Solar PV Connector –Male Open Crimp Contacts (SOL-MC4-11014112)","description":"\u003ch2\u003eStäubli Original MC4 Solar PV Connector – Open Crimp Contacts\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eStäubli Original MC4\u003c\/strong\u003e is the industry-leading solar PV connector trusted by installers and manufacturers worldwide for over 30 years. Featuring Stäubli's proprietary \u003cstrong\u003eMULTILAM contact technology\u003c\/strong\u003e, these connectors deliver consistently low contact resistance and long-term reliability throughout the entire service life of your solar installation.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eApproved for \u003cstrong\u003eDC 1100 V (IEC)\u003c\/strong\u003e and \u003cstrong\u003eDC 1500 V (UL)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAvailable for cable cross-sections up to \u003cstrong\u003e10 mm²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProven MULTILAM contact technology for high long-term stability and minimal power loss\u003c\/li\u003e\n\u003cli\u003eIn accordance with \u003cstrong\u003eNEC 2023\u003c\/strong\u003e – requires a tool to open (plug)\u003c\/li\u003e\n\u003cli\u003eIP65\/IP68 (1 m, 1 h) weatherproof protection when mated\u003c\/li\u003e\n\u003cli\u003eOver \u003cstrong\u003e30 years of field experience\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAlso available as ready-made leads per customer specification\u003c\/li\u003e\n\u003cli\u003eMC4 and MC4-Evo are registered trademarks of Stäubli\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (TÜV\/UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpper Limiting Temperature\u003c\/td\u003e\n\u003ctd\u003e105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection (Mated)\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP68 (1 m, 1 h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection (Unmated)\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Pollution\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Contact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.25 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e16 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact System\u003c\/td\u003e\n\u003ctd\u003eMULTILAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Connection\u003c\/td\u003e\n\u003ctd\u003eCrimping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eCopper, tin plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003ePC\/PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocking System\u003c\/td\u003e\n\u003ctd\u003eLocking Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammability Class\u003c\/td\u003e\n\u003ctd\u003eUL94: V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resistance\u003c\/td\u003e\n\u003ctd\u003eYes (acc. to DLG \/ 2PfG 1911\/04.16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt Mist Spray Test\u003c\/td\u003e\n\u003ctd\u003eDegree of Severity 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Number of Mating Cycles\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range (IEC, 2.5–6 mm²)\u003c\/td\u003e\n\u003ctd\u003eDC 1100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range (UL)\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 50 A (depending on cross-section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eCertifications \u0026amp; Approvals\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTÜV Rheinland: R 60127190\u003c\/li\u003e\n\u003cli\u003eTÜV Rheinland 2 PfG 2330: R 60087448\u003c\/li\u003e\n\u003cli\u003eUL File Number (UL6703 \u0026amp; CSA C22.2 No.182.5 – cULus Listed \u0026amp; UL Recognized): E343181\u003c\/li\u003e\n\u003cli\u003eCQC Certificate: CQC20024256431\u003c\/li\u003e\n\u003cli\u003eJET Certificate: B19T0013\u003c\/li\u003e\n\u003cli\u003eIEC 62852 compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAvailable Variants (Socket PV-KBT4 \/ Plug PV-KST4)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2.5 mm² – Cable OD 5.0–6.0 mm, 5.5–7.4 mm, or 7.0–8.8 mm\u003c\/li\u003e\n\u003cli\u003e4–6 mm² – Cable OD 5.0–6.0 mm, 5.5–7.4 mm, or 7.0–8.8 mm\u003c\/li\u003e\n\u003cli\u003e10 mm² – Cable OD 7.0–8.8 mm (DC 1000 V IEC)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eStäubli PV connectors are designed to guarantee proper operation over their \u003cstrong\u003ewhole lifetime (\u0026gt;25 years)\u003c\/strong\u003e, minimizing risk and maximizing long-term return on investment.\u003c\/p\u003e\u003ch3\u003eDatasheet\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.staubli.com\/content\/dam\/ecs\/catalogs-brochures\/RE\/SOL-MC4-11014112-en.pdf\" target=\"_blank\"\u003e📄 Download Official Stäubli MC4 Datasheet (SOL-MC4-11014112-en.pdf)\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eAssembly Instructions\u003c\/h3\u003e\u003cp\u003eFor assembly instructions, refer to \u003cstrong\u003eMA728\u003c\/strong\u003e at \u003ca href=\"https:\/\/www.staubli.com\/re-downloads.html\" target=\"_blank\"\u003ewww.staubli.com\/re-downloads.html\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eNote: Unmated connectors must be protected from contamination using Stäubli protective caps. Requires a compatible MC4 crimping tool for proper assembly.\u003c\/em\u003e\u003c\/p\u003e","brand":"Stäubli","offers":[{"title":"Default Title","offer_id":46537375547494,"sku":"SOL-MC4-11014112-1","price":2.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7265\/3414\/files\/download.webp?v=1785938621","url":"https:\/\/store.solarcellzusa.com\/products\/staubli-original-mc4-solar-pv-connector-open-crimp-contacts-sol-mc4-11014112","provider":"Solar Cellz Inc","version":"1.0","type":"link"}