{"product_id":"staubli-mc4-evo-2000-solar-pv-connector","title":"Stäubli MC4-Evo 2000 Solar PV Connector","description":"\u003ch2\u003eStäubli MC4-Evo 2000 Connector – Insulating Part \u0026amp; Crimping Contact\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eOriginal MC4-Evo 2000\u003c\/strong\u003e by Stäubli is the connector of choice for high-voltage 2000 V solar PV projects. It combines the proven features of the Original MC4 and the Original MC4-Evo 2, and is the first connector in the market to be dual certified by TÜV Rheinland and UL for DC 2000 V applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eApproved for voltages of up to \u003cstrong\u003eDC 2000 V\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eCombines proven features of the Original MC4 and the Original MC4-Evo 2\u003c\/li\u003e\n  \u003cli\u003eSignificant potential for reducing the Levelized Cost of Energy (LCOE)\u003c\/li\u003e\n  \u003cli\u003ePioneering dual certification: \u003cstrong\u003eTÜV Rheinland\u003c\/strong\u003e (2PfG2925\/01.23 – R50608124) and \u003cstrong\u003eUL\u003c\/strong\u003e (UL6703 \u0026amp; CSA C22.2 No.182.5 – E343181)\u003c\/li\u003e\n  \u003cli\u003eProven \u003cstrong\u003eMULTILAM contact technology\u003c\/strong\u003e with high long-term stability and consistently low performance loss\u003c\/li\u003e\n  \u003cli\u003eOver five billion Stäubli connectors already installed in PV systems worldwide\u003c\/li\u003e\n  \u003cli\u003eCompatible with suitable connectors from the MC4 product family\u003c\/li\u003e\n  \u003cli\u003eFor field and factory assembly\u003c\/li\u003e\n  \u003cli\u003eCan be processed with existing Stäubli tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable Models\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSocket (Female):\u003c\/strong\u003e PV-KBT4-EVO 2000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePlug (Male):\u003c\/strong\u003e PV-KST4-EVO 2000\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAmbient Temperature Range (IEC)\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range (UL)\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUpper Limiting Temperature\u003c\/td\u003e\n\u003ctd\u003e115°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransportation\/Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransportation\/Storage Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;70%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of Protection (Mated)\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP68 (1m, 1h)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDegree of Protection (Unmated)\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eClass (IEC)\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.2 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Impulse Voltage\u003c\/td\u003e\n\u003ctd\u003e27.2 kV (DC 2000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eContact System\u003c\/td\u003e\n\u003ctd\u003eMULTILAM\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eType of Termination\u003c\/td\u003e\n\u003ctd\u003eCrimping\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eCopper, tin plated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInsulation Material\u003c\/td\u003e\n\u003ctd\u003ePC (Polycarbonate)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLocking System\u003c\/td\u003e\n\u003ctd\u003eLocking type\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFlame Class (UL94)\u003c\/td\u003e\n\u003ctd\u003eLevel V0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSalt Mist Spray Test\u003c\/td\u003e\n\u003ctd\u003eDegree of Severity 8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. Number of Mating Cycles\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMax. Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e5000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAmmonia Resistance\u003c\/td\u003e\n\u003ctd\u003eTested per 2PfG1911\/04.16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature Level (IEC TS 63126)\u003c\/td\u003e\n\u003ctd\u003eLevel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTÜV Rheinland Cert. No.\u003c\/td\u003e\n\u003ctd\u003eR50608124 (2PfG2925\/01.23)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eUL Cert. No.\u003c\/td\u003e\n\u003ctd\u003eE343181 (UL6703 \u0026amp; CSA C22.2 No.182.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCable Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCable outer diameter: 5.5–7.4 mm (X series) or 7.0–8.8 mm (II series)\u003c\/li\u003e\n  \u003cli\u003eWire cross-sections: 4 mm², 6 mm², 10 mm² \/ AWG 12, 10, 8\u003c\/li\u003e\n  \u003cli\u003eRated current: up to 70 A (depending on cable size)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIEC 62852 \/ 2PfG 2925\/01.23\u003c\/li\u003e\n  \u003cli\u003eUL 6703 \u0026amp; CSA C22.2 No.182.5 (cULus Listed and UL Recognized)\u003c\/li\u003e\n  \u003cli\u003eIEC TS 63126 Temperature Level 2\u003c\/li\u003e\n  \u003cli\u003eAmmonia resistance per 2PfG1911\/04.16\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDatasheet\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.staubli.com\/content\/dam\/ecs\/catalogs-brochures\/RE\/SOL-MC4-Evo-2000-11014087-en.pdf\" target=\"_blank\"\u003e📄 Download Official Stäubli MC4-Evo 2000 Datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eAssembly Instructions\u003c\/h3\u003e\n\u003cp\u003eFor assembly instructions, refer to \u003cstrong\u003eMA719\u003c\/strong\u003e available at: \u003ca href=\"https:\/\/www.staubli.com\/re-downloads.html\" target=\"_blank\"\u003ewww.staubli.com\/re-downloads.html\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eMC4 and MC4-Evo are registered trademarks owned by Stäubli. © Stäubli 2025.\u003c\/em\u003e\u003c\/p\u003e","brand":"Stäubli","offers":[{"title":"Default Title","offer_id":46537387311206,"sku":null,"price":4.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7265\/3414\/files\/re-mc4-evo-2000-pim.webp?v=1785940274","url":"https:\/\/store.solarcellzusa.com\/products\/staubli-mc4-evo-2000-solar-pv-connector","provider":"Solar Cellz Inc","version":"1.0","type":"link"}