{"product_id":"cps-chint-sch200k-t-us-480-200kw-480v-1500vdc-three-phase-string-inverter","title":"CPS CHINT SCH200K-T-US-480 200kW 480V 1500Vdc Three-Phase String Inverter","description":"\u003ch2\u003eCPS 200 kW-480 V, 1500 Vdc String Inverters for North America\u003c\/h2\u003e\u003cp\u003eThe CPS 200 kW-480 V three-phase string inverters are designed for ground mount applications. The units are high performance, advanced, and reliable inverters designed specifically for the North American environment and grid. High efficiency at \u003cstrong\u003e98.5% peak\u003c\/strong\u003e and \u003cstrong\u003e98.0% CEC\u003c\/strong\u003e, wide operating voltages, broad temperature ranges, and a NEMA Type 4X enclosure enable this inverter platform to operate at high performance across many applications.\u003c\/p\u003e\u003cp\u003eThe CPS 200 kW-480 V products ship with the Distributed or Centralized Wire Box, each fully integrated and separable with AC and DC disconnect switches. Enhanced DC wire boxes allow DC disconnection under short circuit conditions. The CPS FlexOM Gateway enables communication, controls, and remote product upgrades.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUL 1741-SA\/SB \u0026amp; IEEE1547-2018 certified\u003c\/li\u003e\n\u003cli\u003eTouch-safe DC Fuse holders add convenience and safety\u003c\/li\u003e\n\u003cli\u003eCPS FlexOM Gateway enables remote firmware upgrades\u003c\/li\u003e\n\u003cli\u003eIntegrated AC and DC disconnect switches\u003c\/li\u003e\n\u003cli\u003eEnhanced DC wire boxes\u003c\/li\u003e\n\u003cli\u003eCopper- and aluminum-compatible AC connections\u003c\/li\u003e\n\u003cli\u003eNEMA Type 4X outdoor rated enclosure\u003c\/li\u003e\n\u003cli\u003eAdvanced smart inverter functions\u003c\/li\u003e\n\u003cli\u003ekVA headroom yields 200 kW @ 0.95 PF\u003c\/li\u003e\n\u003cli\u003ePID mitigation function\u003c\/li\u003e\n\u003cli\u003eSeparable wire box design for fast service\u003c\/li\u003e\n\u003cli\u003eDistributed or Centralized wire box options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDC Input Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Power\u003c\/td\u003e\n\u003ctd\u003e340 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating DC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e860–1450 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up DC Input Voltage \/ Power\u003c\/td\u003e\n\u003ctd\u003e900 V \/ 250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of MPP Trackers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range for Pnom\u003c\/td\u003e\n\u003ctd\u003e900–1300 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e450 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of DC Inputs\u003c\/td\u003e\n\u003ctd\u003eDistributed Wire Box: 30 PV source circuits, fused; Centralized Wire Box: 1 input circuit, 1–2 terminations per pole, non-fused\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Disconnection Type\u003c\/td\u003e\n\u003ctd\u003eDistributed Wire Box: enhanced DC switches; Centralized Wire Box: enhanced DC disconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Surge Protection\u003c\/td\u003e\n\u003ctd\u003eType II MOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eAC Output Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Output Power\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Apparent Power (selectable)\u003c\/td\u003e\n\u003ctd\u003e200 kVA \/ 210 kVA (@ PF \u0026gt; 0.95)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e480 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e423–528 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid Connection Type\u003c\/td\u003e\n\u003ctd\u003e3D\/PE\/N (neutral optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Output Current @ 480 Vac\u003c\/td\u003e\n\u003ctd\u003e241 A (@ 200 kVA) \/ 253 A (@ 210 kVA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e57–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 (±0.8 adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent THD\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Fault Current Contribution (1 cycle RMS)\u003c\/td\u003e\n\u003ctd\u003e274 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. OCPD Rating\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Disconnection Type\u003c\/td\u003e\n\u003ctd\u003eLoad-rated AC switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Surge Protection\u003c\/td\u003e\n\u003ctd\u003eType II MOV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSystem Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eTransformerless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Efficiency\u003c\/td\u003e\n\u003ctd\u003e98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEC Efficiency\u003c\/td\u003e\n\u003ctd\u003e98.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNight Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eVariable speed cooling fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-22°F to 140°F \/ -30°C to 60°C (derating from 108°F \/ 42°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°F to 158°F \/ -40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e≤13,123 ft \/ 4,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;80 dBA @ 1 m and 77°F (25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eCommunication \u0026amp; Display\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface \u0026amp; Display\u003c\/td\u003e\n\u003ctd\u003eLED indicators; Bluetooth and app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Communication\u003c\/td\u003e\n\u003ctd\u003eModbus RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Data Mapping\u003c\/td\u003e\n\u003ctd\u003eCPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Diagnostics \/ Firmware Upgrade\u003c\/td\u003e\n\u003ctd\u003eStandard \/ (with FlexOM Gateway)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eMechanical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D) – Powerhead\u003c\/td\u003e\n\u003ctd\u003e28.46 × 33 × 13.98 in (723 × 840 × 355 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D) – Wire Box\u003c\/td\u003e\n\u003ctd\u003e23.11 × 33 × 13.98 in (587 × 840 × 355 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – Powerhead\u003c\/td\u003e\n\u003ctd\u003e175 lb (79.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – Wire Box\u003c\/td\u003e\n\u003ctd\u003e106 lb (48 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Installation Angle\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eSafety \u0026amp; Certifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Standards\u003c\/td\u003e\n\u003ctd\u003eUL 1741-SA\/SB Ed. 3, CSA-C22.2 NO.107.1-01, IEEE 1547-2018, FCC Part 15, UL 1699B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Grid Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 1547a-2014, IEEE 1547-2018, CA Rule 21, ISO NE, HECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart-Grid Features\u003c\/td\u003e\n\u003ctd\u003eVolt-RideThru, Freq-RideThru, Ramp-Rate, Specified-PF, Volt-VAR, Freq-Watt, Volt-Watt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eStandard Warranty:\u003c\/strong\u003e 5 Years\u003cbr\u003e\u003cstrong\u003eExtended Warranty Options:\u003c\/strong\u003e 10, 15, and 20 years available\u003c\/p\u003e\u003ch3\u003eDownloads \u0026amp; Documentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.chintpowersystems.com\/wp-content\/uploads\/2026\/06\/CPS-200-kW-480-V-Datasheet-6-29-2026.pdf\" target=\"_blank\"\u003e📄 200 kW-480 V Datasheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.chintpowersystems.com\/wp-content\/uploads\/2026\/05\/CPS-SCH200-250K-T-US-PV-Inverter-User-Manual-May-2026.pdf\" target=\"_blank\"\u003e📘 User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.chintpowersystems.com\/wp-content\/uploads\/2025\/03\/SCH200K-T-US-480_UL1741SAUL1741SBIEEE1547_Cert.pdf\" target=\"_blank\"\u003e✅ NRTL CSA UL Certification (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProduct Page:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.chintpowersystems.com\/200-kw-480-v-1500-vdc-string-inverters-for-north-america\/\" target=\"_blank\"\u003eCPS America – 200 kW-480V String Inverter\u003c\/a\u003e\u003c\/p\u003e","brand":"CHINT Power Systems (CPS America)","offers":[{"title":"Distributed Wire Box","offer_id":46506195746918,"sku":null,"price":17999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/7265\/3414\/files\/250kW-600V-inverter.webp?v=1785525099","url":"https:\/\/store.solarcellzusa.com\/products\/cps-chint-sch200k-t-us-480-200kw-480v-1500vdc-three-phase-string-inverter","provider":"Solar Cellz Inc","version":"1.0","type":"link"}